Case Study: The Particle Problem, Solved

The particle problem, solved.

Tracing and reducing persistent particle counts on a medical device assembly line.

At A Glance

  • Industry: Medical device manufacturing
  • Environment: ISO 7 assembly cleanroom
  • Problem: Particle counts that kept climbing back above spec, driving foreign-material rejects and rework
  • Approach: Trace the particles to their source, then control them at the source
  • Outcome: Counts held within spec, rejects down, throughput restored

The Challenge

A medical device manufacturer was assembling a device built largely from molded plastic and other insulating components. Particle counts on the line kept drifting upward, with intermittent excursions past the ISO limit that no one could reliably explain. The team was wiping down surfaces and re-cleaning parts, but within a shift the counts crept back. Foreign material (FM) was landing on components before sealing, quality holds were mounting, and rework was eating into throughput. They were treating symptoms without a root cause.

The Investigation

MediClean’s technical team started where every particle problem should start: measurement. Using particle counters and real-time monitors, they mapped where and when counts spiked and correlated the data to specific stations on the line. Two sources emerged. First, the insulating device materials — which cannot be grounded — were generating a static field and pulling airborne particulate onto components through electrostatic attraction (ESA). Second, a handling step just before sealing was generating particulate that was never captured at the source. The wipe-downs never had a chance; the line was recontaminating itself faster than the team could clean it.

The Solution

Because MediClean designs and equips the cleanroom itself — soft wall, rigid wall, and hard wall modular cleanrooms built for medical device manufacturing — the controls were integrated into the environment, with airflow, filtration, and station layout tuned to work with them rather than against them. The controls paired static management with source-capture particle control:

  • Ionizing bars and ionizing blowers at the high-risk zones, to neutralize the static field and stop electrostatic attraction before FM could reach the components
  • Ionizing air guns and nozzles for targeted neutralizing and cleaning of parts during assembly
  • Particle Trap systems, including the PT Cube, to source-capture particulate at the point of generation instead of blowing it back into the room
  • A Medical Cleaning System (MCS) workstation to neutralize and remove FM from devices and packaging without recirculating it into the cleanroom
  • Particle counters and monitors kept in place to verify the result and hold the line to spec over time

The Result

Once static was neutralized and particulate was captured where it was created, the counts stopped coming back. The line held within spec across shifts, FM rejects and rework dropped, and throughput recovered — verified by the same monitoring that diagnosed the problem.

The Takeaway

Persistent particle counts are rarely one problem. They are usually a static problem and a particle-generation problem tangled together, and you cannot clean your way out of either. Trace first, then control at the source. And because MediClean designs, equips, and supports the modular cleanroom itself — not just the controls inside it — medical device manufacturers get one coordinated environment from a single source. The same approach applies wherever contamination threatens quality, in any controlled environment.

Have a particle count you can’t explain? Let’s trace it. Talk to MediClean at 833-766-2343 or medicleaninc.com/contact-us. >>>